Saputra, Rizal Rachman (2026) Evaluasi dan Peningkatan Sistem Pencahayaan Menggunakan Pendekatan SketchUp 3D Model dan Simulasi Relux di Kawasan Terminal AKR Nilam Surabaya. Undergraduate thesis, Universitas Muhammadiyah Surabaya.
Pendahuluan_Rizal Rachman Saputra_20221330045.pdf
Download (713kB) | Preview
Bab 1_Rizal Rachman Saputra_20221330045.pdf
Download (1MB) | Preview
Bab 2_Rizal Rachman Saputra_20221330045.pdf
Download (2MB) | Preview
Bab 3_Rizal Rachman Saputra_20221330045.pdf
Download (1MB) | Preview
Bab 4_Rizal Rachman Saputra_20221330045.pdf
Restricted to Repository staff only
Download (2MB) | Request a copy
Bab 5_Rizal Rachman Saputra_20221330045.pdf
Restricted to Repository staff only
Download (1MB) | Request a copy
Daftar Pustaka_Rizal Rachman Saputra_20221330045.pdf
Download (1MB) | Preview
Abstract
Iluminansi merupakan besaran yang menyatakan tingkat penerangan yang diterima oleh suatu permukaan dan dinyatakan dalam satuan lux (lx). Tingkat luminansi yang tidak memenuhi standar yang dipersyaratkan dapat menyebabkan penurunan kualitas penglihatan serta meningkatkan risiko terjadinya kecelakaan kerja. Pada malam hari telah terjadi kecelakaan kerja di Terminal AKR Nilam Surabaya yang disebabkan oleh penerangan yang kurang memadai sehingga mengakibatkan pekerja terpeleset saat pengambilan data ditangki penyimpanan. Setelah dilakukan audit internal oleh perusahaan ditemukan nilai iluminansi kurang dari 50 lux, nilai tersebut kurang dari standar yang ditetapkan perusahaan, kondisi ini menjadi bahan evaluasi bagi pihak perusahaan terkait fasilitas penerangan yang ada di terminal AKR Nilam Surabaya. Penelitian ini bertujuan untuk mengevaluasi dan merekomendasikan sistem pencahayaan yang ada di terminal AKR Nilam Surabaya menggunakan metode kuantitatif dengan pendekatan analitis dan komparatif, pendekatan analitis menggunakan simulasi perangkat lunak relux dan sketchup. Sedangkan pendekatan komparatif digunakan untuk membandingkan hasil analisis kondisi exsisting dan kondisi setelah perbaikan terhadap standar pencahaayan EN 12464. Objek penelitian ini difokuskan pada sistem pencahayaan luar menggunakan lampu jenis floodlight, Perbaikan dilakukan dengan menambah jumlah lampu dari 30 unit menjadi 60 unit. Hasil simulasi setelah perbaikan menunjukkan bahwa tingkat iluminansi meningkat hingga berada di atas 50 lux, sehingga telah memenuhi standar EN 12464. Berdasarkan hasil tersebut, dapat disimpulkan bahwa untuk mencapai tingkat iluminansi minimum sebesar 50 lux, diperlukan penambahan jumlah titik lampu pada area terminal.
======================================================================================================
Illuminance is a measure of the level of light received by a surface and is expressed in lux (lx). Luminance levels that do not meet the required standards can reduce vision quality and increase the risk of workplace accidents. A workplace accident occurred at night at the AKR Nilam Terminal in Surabaya due to inadequate lighting, which resulted in a worker slipping while collecting data in a storage tank. An internal audit by the company found the illuminance value to be less than 50 lux, which is below the company’s established standards. This condition served as a basis for the company’s evaluation of the lighting facilities at the AKR Nilam Terminal in Surabaya. This study aims to evaluate and recommend improvements to the lighting system at the AKR Nilam Terminal in Surabaya using quantitative methods with an analytical and comparative approach. The analytical approach utilized simulation software, Relux, and SketchUp. Meanwhile, a comparative approach is used to compare the results of the analysis of existing conditions and conditions after improvement against the EN 12464 lighting standard. The object of this research is focused on the outdoor lighting system using floodlights. Improvements were made by increasing the number of lamps from 30 units to 60 units. The simulation results after improvement showed that the illuminance level increased to above 50 lux, thus meeting the EN 12464 standard. Based on these results, it can be concluded that to achieve a minimum illuminance level of 50 lux, an increase in the number of light points in the terminal area is required.
| Item Type: | Thesis (Undergraduate) |
|---|---|
| Uncontrolled Keywords: | Relux, luminansi, sketchup |
| Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
| Divisions: | 08. Fakultas Teknik > Teknik Elektro |
| Depositing User: | Rizal Rachman |
| Date Deposited: | 06 May 2026 03:23 |
| Last Modified: | 06 May 2026 03:23 |
| URI: | https://repository.um-surabaya.ac.id/id/eprint/12073 |