Noya, Abri Denny (2026) Perancangan Tangki Penyimpanan Kondensat Tipe Fixed Roof dengan Atap Kerucut (Conical Roof) Berdasarkan API 650 pada Refinery PT Smelting. Undergraduate thesis, Universitas Muhammadiyah Surabaya.
Pendahuluan_Abri Denny Noya_20241331059.pdf
Download (544kB)
Bab I_Abri Denny Noya_20241331059.pdf
Download (114kB)
Bab II_Abri Denny Noya_20241331059.pdf
Download (431kB)
Bab III_Abri Denny Noya_20241331059.pdf
Restricted to Repository staff only
Download (160kB) | Request a copy
Bab IV_Abri Denny Noya_20241331059.pdf
Restricted to Repository staff only
Download (484kB) | Request a copy
Bab V_Abri Denny Noya_20241331059.pdf
Restricted to Repository staff only
Download (107kB) | Request a copy
Daftar Pustaka_Abri Denny Noya_20241331059.pdf
Download (1MB)
Lampiran_Abri Denny Noya_20241331059.pdf
Restricted to Repository staff only
Download (867kB) | Request a copy
Abstract
Peningkatan kebutuhan kondensat pada unit refinery PT Smelting memerlukan penambahan fasilitas penyimpanan yang sesuai standar. Penelitian ini bertujuan merancang tangki penyimpanan kondensat tipe fixed roof dengan atap kerucut (conical roof) berdasarkan API 650 serta memverifikasi hasil desain menggunakan software AMETank.
Perancangan dilakukan dengan metode one-foot method untuk menentukan dimensi tangki, ketebalan minimum pelat, dan stabilitas tangki. Hasil perhitungan manual kemudian dibandingkan dengan hasil verifikasi AMETank.
Hasil penelitian menunjukkan bahwa tangki berkapasitas ±50 m³ dapat dirancang dengan diameter 4m dan tinggi 4,5m. Ketebalan minimum shell hasil perhitungan manual sebesar 2,21mm, 1,97mm, dan 1,73mm, sedangkan hasil AMETank sebesar 2,07mm, 1,86mm, dan 1,66mm. Perbedaan yang terjadi relatif kecil dan seluruh parameter menunjukkan bahwa desain tangki berada pada kondisi aman dan stabil.
=======================================================================================
The increased demand for condensate at the PT Smelting refinery unit requires the addition of storage facilities that meet standards. This research aims to design a fixed-roof condensate storage tank with a conical roof in accordance with API 650 and to verify the design results using AMETank software.
The design was carried out using the one-foot method to determine the tank dimensions, minimum plate thickness, and tank stability. The manual calculations were then compared with the AMETank verification results. The research findings indicate that a tank with a capacity of ±50 m³ can be designed with a diameter of 4m and a height of 4.5m. The minimum shell thickness from the manual calculations was 2.21mm, 1.97mm, and 1.73mm, while the AMETank results were 2.07mm, 1.86mm, and 1.66mm. The differences observed were relatively small, and all parameters indicate that the tank design is in a safe and stable condition.
| Item Type: | Thesis (Undergraduate) |
|---|---|
| Uncontrolled Keywords: | API 650, AMETank, tangki kondensat, fixed roof tank, API 650, AMETank, condensate tank, fixed-roof tank. |
| Subjects: | T Technology > TJ Mechanical engineering and machinery |
| Divisions: | 08. Fakultas Teknik > Teknik Mesin |
| Depositing User: | ABRI DENNY NOYA |
| Date Deposited: | 07 Jul 2026 04:10 |
| Last Modified: | 07 Jul 2026 04:10 |
| URI: | https://repository.um-surabaya.ac.id/id/eprint/12755 |